FMUX01A/Plus Fiber Optical Multiplexer With 100M Ethernet 4,8,12,16 Channels E1/T1/FXO/FXS/Datacom

Strona 2

Chapter 1 Introduction 10 1.8 Ordering Information Classification Item Single Hot Swap Optical Link Optical Link Type Dual Hot Swap Optical Link (1

Strona 3

Appendix 100 A.2 Troubleshooting Guide No. Symptom Probable Cause Corrective Actions 1 VT-100 can not login ■Serial cable connection invalid. ■B

Strona 4

Appendix 101 No. Symptom Probable Cause Corrective Actions 6. Device can not be managed ■Networking service management SNMP may be off ■Device IP

Strona 5

Appendix 102 A.3 Rack Mount Installation Guide MLRCoOptiOrEXMgL A LSLWTX OptiLSLWTX CAE1 E1/TTBRL A MLRCoOptiOrEXMgL A LSLW

Strona 8 - 1.4 Technical Specifications

Chapter 2 Installation 11 Chapter 2 Installation This chapter provides the information needed to install the FMUX01A/Plus. It is important to follo

Strona 9 - 1.7 Power Supply

Chapter 3 Panel Description 12 Chapter 3 Panel Description 3.1 Front Panel (1) Optical 1/2 : LSRON LED Yellow light when the laser is on

Strona 10 - 1.9 Rear Panel View

Chapter 3 Panel Description 13 3.2 Rear Panel Power Switches : On/Off switch for each power main The FMUX01A/Plus provides three major types o

Strona 11 - Chapter 2 Installation

Chapter 3 Panel Description 14 (d) V.35 tributary card This 4 channel V.35 card, also requires HD68 to 4xMB34F adapter cable to connect to V.35 inte

Strona 12 - Chapter 3 Panel Description

Chapter 4 Quick Start 15 Chapter 4 Quick Start The FMUX01A/Plus control interface provides two modes of operation. First, a serial console port, f

Strona 13 - 3.2 Rear Panel

Chapter 4 Quick Start 16 4.1.2 Console Login The factory default username is 'admin' and password is '1234'

Strona 14

Chapter 4 Quick Start 174.1.4 Equipment Status The screen is divided horizontally, displaying the local unit <Lo> on top and

Strona 15 - Chapter 4 Quick Start

Chapter 4 Quick Start 18 The following shows the screen after setting service mode "in service" (IS), setting unframed, line code B8ZS and

Strona 16

Chapter 4 Quick Start 19 The menu bar at the bottom of the screen now selects the tributary cards for the remote unit. Use the fu

Strona 18

Chapter 4 Quick Start 20 The following screen shows that T1 and E1 for both local and remote units are in-service and without alarms. The "G&qu

Strona 19

Chapter 4 Quick Start 21 4.1.7 Ethernet Trunk Configuration 4.1.7.1 Introduction The trunk Ethernet refers to the 100Mbps trunk speed within the 155

Strona 20

Chapter 4 Quick Start 22 The Trunk Ethernet Configuration menu is displayed below. There are three options. The first option, General Configuration,

Strona 21

Chapter 4 Quick Start 23 Outband (Mgmt Port) In this scenario, the two ports LAN1 and LAN2 will link to the aggregate channel. The manage

Strona 22

Chapter 4 Quick Start 24 Inband+Outband (Mgmt Port) In this scenario, the two front panel ports, LAN1 and LAN2, connect to the fiber aggr

Strona 23

Chapter 4 Quick Start 25 4.1.8 Profile Management The active changes need to be saved if they are to be used during next power up or reboot. Use [ES

Strona 24

Chapter 4 Quick Start 26 4.1.8.2 Profile Operation The FMUX01A/Plus has three profile locations in non-volatile memory. Profile I and Profile II may

Strona 25

Chapter 5 Operation 27 Chapter 5 Operation This chapter will describe in more detail all the operational menu screens and functions of the FMUX01A/P

Strona 26

Chapter 5 Operation 28 The system has built in self-diagnostic functions that are performed during the booting procedure. The self-diagnostic functi

Strona 27 - Chapter 5 Operation

Chapter 5 Operation 29 5.2 Main Menu Note : Not all terminal emulation programs support the use of function keys. There

Strona 28 - Chapter 5 Operation

LEGAL The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union T

Strona 29 - 5.2 Main Menu

Chapter 5 Operation 30 5.3 System Configuration System Configuration the menu includes the following selections. System In

Strona 30 - 5.3 System Configuration

Chapter 5 Operation 31 5.3.1 System Information Configuration The system administrator can key in the System Name with less t

Strona 31

Chapter 5 Operation 32 5.3.2 Device Networking Configuration The system administrator can set the system device IP, subnet mas

Strona 32

Chapter 5 Operation 33 5.3.3 User Account Management FMUX01A/Plus provides three levels of the user groups. Admin :the admi

Strona 33

Chapter 5 Operation 34 The default Auto-Logout Seconds is 0, which means the auto-logout function is disabled. Administrator c

Strona 34

Chapter 5 Operation 35 5.3.4 SNMP Agent Configuration The FMUX01A/Plus can assign four sets of the Manager IP address to send Tr

Strona 35

Chapter 5 Operation 36 5.3.5 Software Upgrade Configuration 5.3.5.1 Remote Server Method FMUX01A/Plus can support System So

Strona 36

Chapter 5 Operation 37 5.3.5.2 Local File Method For Local File source selection : The screen will show the available file s

Strona 37

Chapter 5 Operation 38 5.3.6 Software Upgrade and Reboot Operation This function is used to upgrade the local and/or remote un

Strona 38

Chapter 5 Operation 39 When user executes the Upgrade command item in local or remote side, the display will show the status : "Start upgradin

Strona 39

CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St. Neihu, Taipei, 114 Taiwan Phon

Strona 40

Chapter 5 Operation 40 When the unit first boots, the profile selection screen will be displayed. Profile I will load by default without any user in

Strona 41

Chapter 5 Operation 41 5.3.7 Network Time Synchronization The system provides the ability to synchronize time to time server u

Strona 42

Chapter 5 Operation 42 5.3.8 Scheduling Job Management The Scheduling Job Management function provides the automatic timely

Strona 43

Chapter 5 Operation 43 Job Type : Periodic (set a time period to do some scheduled task) One shot (perform a scheduled t

Strona 44

Chapter 5 Operation 44 5.3.9 Networking Service Management The system can turn on or turn off the functions of the SNMP Agent,

Strona 45

Chapter 5 Operation 45 5.3.10 Network Trouble Shooting Operation This function can provide tests to determine whether links to

Strona 46

Chapter 5 Operation 46 When target IP ping succeeds, the display will show the following : When target IP ping fails, the disp

Strona 47

Chapter 5 Operation 47 5.3.11 LCD Login Configuration User can define the 'key combination' login password for the

Strona 48

Chapter 5 Operation 48 5.3.12 Event Management FMUX01A/Plus provides Event Management function which includes Event Class Proce

Strona 49

Chapter 5 Operation 49 5.3.12.1 Event Class Processing Configuration The event class processing configuration function can set

Strona 50

Table of Contents i Table of Contents Chapter 1 Introduction...

Strona 51

Chapter 5 Operation 50 5.3.12.2 Event Alarm Processing Configuration The event alarm processing configuration function can set

Strona 52

Chapter 5 Operation 51 5.3.13 System Profile Management Use 'ESC' to return to the Main Menu, select item "1" and press [F2] to

Strona 53

Chapter 5 Operation 52 5.3.13.2 Profile Operation The FMUX01A/Plus has three profile locations in non-volatile memory. Profile I and Profile II may

Strona 54

Chapter 5 Operation 53 5.4 Tributary Slot Interface Selection There are two ways to configure these tributary cards one is in this screen and the o

Strona 55

Chapter 5 Operation 54 5.4.1 E1 Interface Configuration You can edit E1 Parameters for each channel or all channels of

Strona 56

Chapter 5 Operation 55 [F2] Edit channel screen is shown below : The FMUX01A/Plus has two service modes which can select : O

Strona 57 - DCE DTE

Chapter 5 Operation 56 5.4.2 V.35 Interface Configuration If the EOC (Embedded Operations Channel) connection is closed, a symbo

Strona 58

Chapter 5 Operation 57 You can set the clock source for TC/RC as well as the polarity of TC and/or RC clock to fit the requirements of different DTE

Strona 59

Chapter 5 Operation 58 5.4.3 T1 (DS1) Interface Configuration If the EOC (Embedded Operations Channel) connection is closed, a s

Strona 60

Chapter 5 Operation 59 5.4.4 FXO/FXS Interface Configuration If the EOC (Embedded Operations Channel) connection is closed, a sy

Strona 61

Table of Contents ii 5.4 Tributary Slot Interface Selection...

Strona 62

Chapter 5 Operation 60 5.5 Optical Interface Parameters Configuration [F2] Edit channel screen is shown below :

Strona 63

Chapter 5 Operation 61 [F4]ALS (Auto Laser Shutdown) : Please refer to the definition of ITU-T G.664, when FMUX01A/Plus detects " LOS " a

Strona 64

Chapter 5 Operation 62 5.6 Trunk Ethernet Parameters Configuration 5.6.1 Introduction The trunk Ethernet refers to the 100Mbps trunk speed within th

Strona 65

Chapter 5 Operation 63 5.6.3 Trunk Ethernet General Parameter Config The Trunk Ethernet Configuration menu is displayed below. There are three optio

Strona 66

Chapter 5 Operation 64 Outband (Mgmt Port) In this scenario, the two ports LAN1 and LAN2 will link to the aggregate channel. The manageme

Strona 67

Chapter 5 Operation 65 Inband+Outband (Mgmt Port) In this scenario, the two front panel ports, LAN1 and LAN2, connect to the fiber aggreg

Strona 68

Chapter 5 Operation 66 The following shows how the Management Modes can be used to secure and isolate the management traffic. In the following sc

Strona 69

Chapter 5 Operation 67 5.6.4 Trunk Ethernet Parameter Config The Trunk Ethernet Parameters Config screen will show the LAN1, LAN2 and SNMP managemen

Strona 70

Chapter 5 Operation 68 5.6.5 Trunk Ethernet Rate Configuration Each of three ports, LAN1, LAN2 and SNMP support individual bandwidth control for ing

Strona 71

Chapter 5 Operation 69 5.7 Data Port Parameter Configuration On the front panel of the FMUX01A/Plus is an RJ-45 port labeled 'RS-232'. Thi

Strona 72

Chapter 1 Introduction 7Chapter 1 Introduction 1.1 Product Description The FMUX01A/Plus is a powerful optical multiplexer which can aggregate up to

Strona 73

Chapter 5 Operation 70 5.8 PM Threshold Configuration This function is used to setup the threshold values that meet the requi

Strona 74

Chapter 5 Operation 71 5.8.1 E1 Interface Threshold Setting You can use the function keys to modify the selected traffic link.

Strona 75

Chapter 5 Operation 72 [F1] Line : LCV : Line Code Violation LES : Line Error Second LSES : Line Several Error Second

Strona 76

Chapter 5 Operation 73 5.8.2 Aggregate Interface Threshold Setting You can use the function keys to modify the selected traf

Strona 77

Chapter 5 Operation 74 5.9 Fault Management Parameters Configuration FMUX01A/Plus provides fault management function by setting

Strona 78 - 5.1 OE Protection Switching

Chapter 5 Operation 75 5.9.2 Power Failure Monitoring Parameter Config This provides the function for power monitoring. When &qu

Strona 79

Chapter 5 Operation 76 5.10.1 External Clock Config User can select OOS or IS to turn on or off the external clock input. If

Strona 80

Chapter 5 Operation 77 5.10.2 External Clock Monitoring If the External Clock Module is found, the EquipStatus will show a

Strona 81

Chapter 5 Operation 78 5.1 OE Protection Switching User can configure the active OE module as either locked or as released.

Strona 82

Chapter 5 Operation 79 Automatic laser shutdown and restart concept The ALS mechanism implemented in FMUX01A/Plus is compliant with ITU Recommendati

Strona 83 - 5.13 Performance Monitoring

Chapter 1 Introduction 8 1.3 Product Features  Channel Capacity :4, 8, 12, 16 E1, T1, or data communication service  Tributary card types : E1 i

Strona 84

Chapter 5 Operation 80 5.12 Equipment Status Monitoring On the equipment status monitoring screen, the user can get an overall view of the alarm sta

Strona 85 - 5.14 Path Alarm Monitoring

Chapter 5 Operation 81 Local site tributary card setup : System Name: Eq

Strona 86 - 5.15 Loopback/V.54 Testing

Chapter 5 Operation 82 Remote site tributary card setup : System Name: E

Strona 87 - Local site Remote site

Chapter 5 Operation 83 5.13 Performance Monitoring The performance monitoring screen will show the valid quarters (15 minute i

Strona 88 - Local Site Remote Site

Chapter 5 Operation 84 There are five types of PM: 1. CurrQuart (Current 15 minute interval) 2. HistQuart (History Quarter) 3

Strona 89

Chapter 5 Operation 85 5.14 Path Alarm Monitoring This screen shows all of alarm status for all monitored paths. Some diagno

Strona 90 - 5.16 PRBS Test

Chapter 5 Operation 86 5.15 Loopback/V.54 Testing For diagnostic purposes, low speed E1 or V.35 data channels and high speed

Strona 91

Chapter 5 Operation 87 5.15.1 Loopback Testing Introduction There are four types of loopback functions for the E1/T1 Module : Tributary Local Loop

Strona 92 - 5.17 Event Browser

Chapter 5 Operation 88 There are three types of loopback functions for the V.35 Module : a. Analog (ANA) Loopback : b. Digital (DIG) Loopback c. R

Strona 93 - Chapter 6 LCD Operation

Chapter 5 Operation 89 Info :function key [F8] If the EOC (embedded operations channel) is broken, such as when running the aggregate remote loopba

Strona 94 - 6.1 LCD Menu Tree

Chapter 1 Introduction 9 1.4.3 T1 module  Channel Capacity : 4 channels per module  Bit Rate : 1.544Mbps ± 32ppm  Line Code : B8ZS / AMI  Fra

Strona 95

Chapter 5 Operation 90 5.16 PRBS Test The PRBS (pseudo- random binary sequence) pattern is 215-1(unframed). E1, T1 and V.3

Strona 96

Chapter 5 Operation 91 Regarding the PRBS test mode, please refer to the following : One way PRBS test setup : Round trip PRBS

Strona 97

Chapter 5 Operation 92 5.17 Event Browser The Event Browser is used to view all of the alarm events in both current memory and

Strona 98

Chapter 6 LCD Operation 93 Chapter 6. LCD Operating Instructions FMUX01A/Plus provides an easy way to set the configuration, do maintenance, and con

Strona 99

Chapter 6 LCD Operation 94 6.1 LCD Menu Tree Password : _ _ _ _ (Modify Password refer to 5.3.10) ---Tb Config ----E1 [Site/Slot/Ch] ----Fr

Strona 100 - A.2 Troubleshooting Guide

Chapter 6 LCD Operation 95 ---Lan Port Conifg [Site][Port] ----Service (IS/OOS) ----AutoNeg (ON/OFF) ----Duplex (Full/Half) ----Speed (1

Strona 101 - Appendix

Chapter 6 LCD Operation 96 ---System ----Profile Operation [Site] ----Profile Id (1/2) ---FM Config ----Pwr Fail Mon Cfg [Site/ PwrID]

Strona 102

Chapter 6 LCD Operation 97 --- PRBS Testing[Site] ---- E1 [Slot/Ch] ----PTGEN (ON/OFF) ----PTANA (ON/OFF) ----PTANA Result (Status :Erro

Strona 103

Chapter 6 LCD Operation 98

Strona 104

Appendix 99 Appendix A.1 External User Interface : Async Serial / RS-232 User VT-100 interface / RS232 interface : Signal Ground connects to