CTC Union FMUX-01A Dokumentacja Strona 83

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 82
Chapter 5 Operation
83
5.13 Performance Monitoring
The performance monitoring screen will show the valid quarters (15 minute intervals) and valid days (24
hour intervals) that have been counted for each card (Fiber Aggregate; E1 or T1 type card). Select the card
and access the next screen to see the detail performance data by pressing [F2].
[F6] Reset : to clear all PM counters on the selected monitoring path
[F7] Reset All : to clear all PM counters on the All monitoring paths
Performance monitoring is only supported on E1 or T1 card. The E1S card (unframed) only supports BPV
error but cannot support CRC4 error monitoring (framed mode card is required for that).
System Name: Performance Monitoring
[F3]Site: All [F4]SlotId: All [F5]ChId: All
+-----------------------------------------------------------------------------+
|[F1]St#/Sl#/Ch# ValidQuarter ValidDay Alarm |
|Aggr/Lo 3 0 - |
|E1/Lo/1/1 3 0 - |
|E1/Lo/1/2 3 0 -#|
|E1/Lo/1/3 3 0 -#|
|E1/Lo/1/4 3 0 -#|
|Aggr/Re 1 0 -#|
|E1/Re/1/1 1 0 -#|
|E1/Re/1/2 1 0 -#|
|E1/Re/1/3 1 0 -#|
|E1/Re/1/4 1 0 -#|
| #|
| #|
| #|
+-----------------------------------------------------------------------------+
+-----------------------------------------------------------------------------+
| Monitor[F2] Reset[F6] Reset All[F7] Back[ESC] |
Przeglądanie stron 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 103 104

Komentarze do niniejszej Instrukcji

Brak uwag