CTC Union SHDSL Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking CTC Union SHDSL. CTC Union SHDSL User manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 162
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - SHDTU03b NTU Series

SHDTU03b NTU Series G.SHDSL.bis TDM NTU

Strona 2

10 1.1 Features y Standard G.SHDSL.Bis ITU G.991.2 (2004) supports improved reach/speed and greater interoperability y Fast and cost-effective pro

Strona 3

100 Setup E1 Parameter, AIS AIS (Alarm Indication Signal) is a method to inform the remote connection that there is a signal o

Strona 4

101 Setup E1 Parameter, Build Out The SHDSL.Bis NTU can support both unbalanced E1 at 75 ohms (BNC) and balanced E1 at 120 ohms (R

Strona 5 - Tables of Contents

102 5.4.4. Configure Serial parameters When using the Serial interface, select the Serial item and press [ENTER] or [RIGHT]. The serial settings in

Strona 6

103 Setup Serial Parameter, Data Rate For 2-wires with Annex A and B, the rate can be adjusted in increments of 64kbps from 64kbps

Strona 7

104 Setup Serial Parameter, RTS The behavior of the RTS (Request To Send) signal may be set in one of two ways. When set 'on&ap

Strona 8

105 Setup Serial Parameter, DSR The behavior of the DSR (Data Set Ready) signal may be set in one of three ways. When set 'on&a

Strona 9 - 1. Introduction

106 Setup Serial Parameter, Delay The delay setting is used to cause a delay for CTS to follow RTS. The delay setting may be set 0,

Strona 10 - 1.2 Specification

107 Setup Ethernet Parameter, Data Rate – Rate type There are two modes: Nx64K model and T1 mode. When the remote side has T1 inter

Strona 11 - 1.3 Applications

108 Setup Interface Parameter, Negotiation The Ethernet settings include the choice between auto-negotiation (default) or forced mod

Strona 12 - 2.1 Front Panel

109 Setup Ethernet Parameter, Speed When auto negotiation is Disable, the forced mode settings for speed can be set between: 10M and

Strona 13

11 Performance Monitoring • ES, SES, UAS, LOWS for SHDSL • ES, SES, UAS for E1 • Alarms and Errors for SHDSL or interface Loopback Tests (for E1,

Strona 14

110 Setup T1 Parameter, Channel The Superframe(SF) (also called D4 or 193S) framing format defines a superframe as 12 frames. The E

Strona 15 - 2.2 Rear Panel

111 Setup T1 Parameter, Time Slot number and First time slot For fractional T1, the data rate is from 64k(N=1) to 1536k(N=24), acco

Strona 16

112 The table of number of time slot vs. 1st time slot: Channel Number of slot 1st slot 24 1 23 1~2 22 1~3 21 1~4 20 1~5 19 1~6 18 1~7 17 1~8 16 1~9

Strona 17

113 Setup T1 Parameter, AIS AIS (Alarm Indication Signal) is a method to inform the remote connection that there is a signal or sy

Strona 18

114 5.4.8. Restore factory default The G.SHDSL .Bis NTU can restore all settings to the original factory settings simply by going to the setting me

Strona 19 - 2.3 Installation

115 Ethernet Setup Ethernet Rate Type Setup Ethernet Rate setup Ethernet Auto Config setup Ethernet Speed setup Ethernet Duplex Nx64K 36 Enable Auto

Strona 20 - 2.3.1. E1/T1 Interface

116 T1+ Serial setup T1 Channel setup T1 Slot Number setup T1 First Slot setup T1 AIS setup T1 Lbo setup Serial Interfac

Strona 21 - 2.3.2. Serial Interface

117 5.5 Reboot In main menu, move the cursor to reboot and press [ENTER]. The device will reboot after confirming.

Strona 22 - 2.3.3. Ethernet Interface

118 5.6 View the system status You can use the status command to view the status of SHDSL, E1, Serial and Ethernet as well as statistic and clear t

Strona 23 - Protective earth:

119 The SHDSL status will display a real-time status of the DSL on local side and remote side if connected. The monitoring window

Strona 24 - 3.1 Keypad

12 2. Getting to know the SHDSL.bis NTU This chapter shows the front and rear panel and how to install the hardware. The models listing on G.SHDSL

Strona 25 - 3.2 Main menu Tree

120 The interface status will display a real-time status of the interface on local side and remote side if connected. The monitorin

Strona 26

121 The table of SHDSL line rate vs. data rate: Data Rate (kbps) SHDSL Line rate Number of time slot for E1 Nx64K for Serial and Ethernet 5696(n=89)

Strona 27

122 5.6.3. View the Statistics Select Loc_statistics command to show the Local statistics information in 15 minutes or 24 hour via [TAB] to choose.

Strona 28

123 For E1 Interface model, there are SHDSL and E1 items. View the performance monitor data for the selected interval 15 minutes: V

Strona 29

124 For Serial and Ethernet Interface model, there is only the SHDSL item. View the performance monitor data for the selected interval 15 minutes:

Strona 30

125 When clear the statistic log file, select clear and press [ENTER]. If you want to show the remote side’s statistics, please

Strona 31

126 The following are commonly used acronyms: ES Number of errored seconds in which one or more CRC (Cyclic Redundancy Check) error events occurr

Strona 32

127 5.7 View System Configuration By using show command, you can view the system configuration. Select show and press [ENTER] or [RIGHT].

Strona 33

128 Our cursor is already on the System command, so press ENTER and the following screen will display the general system information.

Strona 34

129 5.7.2. Show system with listing format To show the system configuration, please select Config and press [ENTER] or [RIGHT]. The screen will prom

Strona 35

13 2.1.3. Ethernet interface model 2.1.4. Multi-interfaces model Front panel can be separated into three parts: LCD display, L

Strona 36

130 For Ethernet interface mode: For E1 and Serial interface mode:

Strona 37

131 For E1 and Ethernet interface mode: 5.7.3. Show system with script format To show the system script file, please select Sc

Strona 38

132 For E1 interface mode: For Serial interface mode:

Strona 39

133 For Ethernet interface mode: For E1 + Serial interface mode:

Strona 40

134 For E1 + Ethernet interface mode:

Strona 41

135 5.8 Upgrade This section will introduce how to upgrade the kernel and FPGA code of G.SHDSL .Bis NTU. Select upgrade in main menu and press [ENT

Strona 42

136 During the upgrade, you can see the following: If you want to upgrade the FPGA code: Select FPGA and press [ENTER] or [RIGHT].

Strona 43

137 During the upgrade process, you will see the following: Below shows the remote upgrade feature:

Strona 44

138 During the upgrade, the display will look like the following: Before upgrading the NTU, you must have the Kernel code and FPGA

Strona 45

139 5.9 Diagnostic The diagnostic facility allows you to test the different aspects of your G.SHDSL .Bis NTU to determine if it is working properl

Strona 46

14 On E1 line is connected. SYN Green Off E1 line is dropped. Blink There are error seconds. ERR Red Off There is not any error second. On Loopba

Strona 47

140 If the device has just been connected or the DSL is still under handshaking, there will not are farend line, farend payload and V.54.There are no

Strona 48

141 The SHDSL.bis NTU supports Bit Error Rate Testing (BERT). To configure the BERT, move the cursor to BerTest and press [ENTER] or [RIGHT].

Strona 49

142 5.10 Exit For exiting the system without saving any configuration, you can use exit command to exit. Select exit and press [ENTER] or [RIGHT].

Strona 50

143 When the system has been disconnected, user can see the close screen. You can press Space key to restart. The new login screen w

Strona 51

144 6. Appendix 6.1 Abbreviations AIS Alarm Indication Signal AMI Alternate mark inversion ASYM Asymmetric ATM Asynchronous Transfer Mode B8ZS

Strona 52

145 I/F Interface ITU International Telecommunication Union ITU-T ITU-Telecommunication Standardization Sector LBO Line Build Out LIU Line Interfa

Strona 53

146 STU-R-EXTCLK STU-R external clock SYM Symmetric SYNC Synchronization TC-PAM Trellis Coded Pulse Amplitude Modulation TDM Time Division Multipl

Strona 54

147 6.2 Serial Interface Pin Assignments The table below displays Serial Interface Pin Assignments for the DCE Mode . Function Abbrev. Direction

Strona 55

148 6.3 V.35 DB25(M) to M.34(F) adaptor Cable If the DTE (Data Terminal Equipment) connector is using 34-pin Winchester type, we must use the cable

Strona 56

149 V.35 interface (34-pin Winchester type) contains the following signals: Pin Signal Abbr. DTE DCE A Chassis Ground FGND --- --- B Signal Gro

Strona 57

15 2.2 Rear Panel 2.2.1. E1/T1 Interface Model AC power input version The rear panel of this model is including power switch, AC power soc

Strona 58

150 6.4 X.21 DB25(M) to DB15(F) adaptor Cable For X.21 applications, we must use the DB-25 to DB-15 adaptor cable to connect to a X.21 DTE DB-15 mal

Strona 59

151 The pin out of DB-15 connector on X.25 adaptor cable: Pin Signal Abbr. DTE DCE 1 Shield -- -- -- 2 Transmit (A) TA Out In 3 Control (A) C

Strona 60

152 DCD1RXD2TXD3DTR4GND5DSR6RTS7CTS8DSR1DCD2DTR3GND4RXD5TXD6CTS7RTS8NC9DB9 (Female) RJ-45 6.5 Console Cable The front view of RJ-45 console cabl

Strona 61

153 6.6 E1/T1 Balanced Cable The front view of RJ-48C E1/T1 balance cable socket on rear panel: The pin out of RJ-48C plug

Strona 62 - 3.7.1. Loopback function

154 6.7 E1 Unbalanced Cable Connections to the E1 BNC ports are made using a 75-ohm coaxial cable with a bayonet-style twist-lock BNC conne

Strona 63

155 6.8 Ethernet Cable The Ethernet cables should be 4 pair unscreened cable (UTP) or screened (STP) of type CAT5 (or higher). Both crossed a

Strona 64

156 6.9 DSL Cable The front view of DSL cable socket on rear panel: The pin out of RJ-45 modular jack on DSL cable: Pin Number Descri

Strona 65 - 3.7.2. BER Test function

157 6.10 Power Cord The front view of IEC-320 C6 type AC Inlet on rear panel: The pin out of AC Inlet connector: Pin number Desc

Strona 66 - 4. Parameters Table

158 6.11 Illustration of Loopback connection device (E1) RJ-48C Pin number Description 4 Transmit Ring 3 Rx Shield 1 Receive Ring 6 TX Shie

Strona 67 - 4.2 SHDTU03b-Data

159 6.12 Illustration of Loopback connection device (Serial) DB-25(M) Pin number Signal Description 2 TD(A) Transmit Data 14 TD(B) Transmit D

Strona 68 - 4.3 SHDTU03b-ET100

16 2.2.2. Serial Interface Model AC power input version The rear panel of this model is including power switch, AC power socket, RJ-45 for

Strona 72 - E1+Serial □E1+Ethernet

17 2.2.3. Ethernet Interface Model AC power input version The rear panel of this model is including power switch, AC power socket, RJ-45 fo

Strona 73 - E1+Ethernet

18 2.2.4. Multi-interfaces in one Model DC power input version The rear panel of this model is including power switch, AC power socket, RJ-4

Strona 74 - 4.5 SHDTU03b-E1/T1

19 2.3 Installation Note: To avoid possible damage to this NTU, do not turn on the product before hardware installation. (a) Plug the power cord

Strona 76 - 4.6 SHDTU03b-31T

20 2.3.1. E1/T1 Interface AC power input version DC power input version AC & DC dual power input v

Strona 77

21 2.3.2. Serial Interface AC power input version DC power input version AC & DC dual power input vers

Strona 78

22 2.3.3. Ethernet Interface AC power input version DC power input version AC & DC dual power input vers

Strona 79

23 ! Protective earth: The marked lug or terminal should be connected to the building protective earth bus. The function of protective earth do

Strona 80

24 3. Configuration with Keypad and LCD This chapter provides information about the configuration of your G.SHDSL .Bis NTU via front panel LCD disp

Strona 81

25 3.2 Main menu Tree Model vs. Interface modes support (table 1): Model Interface modes support SHDTU03b-E1; SHDTU03bA-E1 E1 interface model E1 i

Strona 82

26 After turning on device, the LCD display will prompt G.SHDSL .BIS NTU. Press Enter to enter. The display will follow the sub-menus as in the follow

Strona 83 - T1+Ethernet

27 3.3 Menu tree for SHOW STATUS You can check the status via LCD display. The SHOW STATUS menu tree is as following.

Strona 84

28 For more detail on these sub-menus, please refer to following:

Strona 85 - 5.1 Login Procedure

29 3.4 Menu tree for SHOW STATISTICS The product can display two kinds of statistics data: (a) Current 15 minutes period and 96 previous 15-minu

Strona 86 - 5.2 Window structure

CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu District Taipei 114 Taiwan

Strona 87 - 5.3 Main Menu Summary

30 Model vs. Interface modes and statistics support: Model Interface modes support SHDSL statistics support ES ,SES,UAS,LOSWE1 statistics support ES,

Strona 88 - 5.4 Configuration

31 3.4.1. Show Statistic on E1 Interface

Strona 89

32 3.4.2. Show Statistic on Serial/Ethernet/T1 Interface

Strona 90

33 3.5 Menu tree for SYSTEM SETUP You can setup five interface modes via LCD display.

Strona 91

34 3.5.1. Sub-Menu tree for SETUP SHDSL SETUP SHDSL Selection items SETUP MODE STU-R, STU-C-INTCLK, STU-C-EXTCLK SETUP ANNEX A,

Strona 92

35 3.5.2. Sub-Menu tree for SETUP E1 Interface SYSTEM SETUP Î SETUP E1 E1 parameter setting: E1 Items Setting Channel

Strona 93

36 Framer Setting: Framer Slot Number First Slot PCM31 FAS 1 to 31 1 to 31 PCM31C FAS+CRC4 1 to 31 1 to 31 PCM30 FAS+CAS 1 to 30 1 to 31 (c

Strona 94

37 25 1~6 24 1~7 23 1~8 22 1~9 21 1~10 20 1~11 19 1~12 18 1~13 17 1~14 16 1~15 15 1~15,17 14 1~15,17~18 13 1~15,17~19 12 1~15,17~20 11 1~15,17~21 10 1

Strona 95 - Framing

38 16 1~15 14 1~15,17~18 12 1~15,17~20 10 1~15,17~22 8 1~15,17~24 6 1~15,17~26 4 1~15,17~28 2 1~15,17~30 Note: When SHDSL.bis uses 2-pairs(4-wires),

Strona 96

39 3.5.3. Sub-Menu tree for SETUP SERIAL Interface SYSTEM SETUP Î SETUP SERIAL

Strona 97 - Unframed E1

Legal The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union T

Strona 98

40 Serial interface control signals settings: Serial Items Setting INTERFACE V.35 X.21(RS-530) T1 mode Annex A/B 1 ~ 36 2-wires Annex F/G 1 ~ 89 A

Strona 99

41 The handshake signal direction between DCE and DTE The below diagram shows CTS follow RTS, DSR follow DTR The RTS delay tim

Strona 100 - Setup E1 Parameter, AIS

42 3.5.4. Sub-menu tree for SETUP Ethernet Interface SYSTEM SETUP Î SET UP ETHERNET If you set Ethernet Auto Negotiation to En

Strona 101

43 3.5.5. Sub-menu tree for SETUP T1 Interface SYSTEM SETUP Î SETUP T1 T1 parameter setting: T1 Items Setting Channel SF ESF

Strona 102

44 The table of number of time slot vs. 1st time slot: Annex A/B/F/G 2-wire Channel Number of slot 1st slot 24 1 23 1~2 22 1~3 21 1~4 20 1~5 19 1~6

Strona 103

45 3.5.6. Application of STU-R configuration follow STU-C Some configurations on STU-R side can follow STU-C side after DSL link up is finish. Such

Strona 104 - Setup Serial Parameter, CTS

46 3.5.7. Application of Multi-interface Dual interface vs. Dual interface Case 1 E1(Unframed)+ Serial interfac

Strona 105

47 Table of E1+ Serial interface or E1+Ethernet interface mode on both sides Annex A /B (2-wires) E1 interface Serial interface Ethernet interface C

Strona 106

48 16 1 1~20 15 1 1~21 14 1 1~22 13 1 1~23 12 1 1~24 11 1 1~25 10 1 1~26 9 1 1~27 8 1 1~28 7 1 1~29 6 1 1~30 5 1 1~31 4 1 1~32 3 1 1~33

Strona 107

49 30 1 1~59 29 1 1~60 28 1 1~61 27 1 1~62 26 1 1~63 25 1 1~64 24 1 1~65 23 1 1~66 22 1 1~67 21 1 1~68 20 1 1~69 19 1 1~70 18 1 1~71 17 1

Strona 108

Tables of Contents 1. INTRODUCTION ...

Strona 109

50 26 1 1~46 24 1 1~48 22 1 1~50 20 1 1~52 18 1 1~54 16 1 1~56 14 1 1~58 12 1 1~60 10 1 1~62 8 1 1~64 6 1 1~66 4 1 1~68 2 1 1~70 Annex F/

Strona 110 - Setup T1 Parameter, Channel

51 Case 5 T1(Unframed)+ Serial interface Å---------Æ T1(Unframed)+ Serial interface Case 6 T1(Framed)+ Serial

Strona 111

52 Table of T1+ Serial interface or T1+Ethernet interface mode on both sides Annex A/B (2-wire) T1 interface Serial interface Ethernet interface Cha

Strona 112 - Setup T1 Parameter, LBO

53 6 1 1~83 5 1 1~84 4 1 1~85 3 1 1~86 2 1 1~87 1 1 1~88 Annex A/B (4-wire) T1 interface Serial interface Ethernet interface Channel Number of slot

Strona 113 - 5.4.7. Remote configuration

54 Dual interface vs. Single interface Case 9 E1(framed)+ Serial interface Å---------Æ E1(framed) Case 10 E1(framed)+Ethernet

Strona 114

55 Table of E1+ Serial interface to E1 interface and E1+Ethernet interface to E1 interface mode on both sides Annex A /B/F/G (2-wires) E1 interface

Strona 115

56 13 1 1~17 12 1 1~18 11 1 1~19 10 1 1~20 9 1 1~21 8 1 1~22 7 1 1~23 6 1 1~24 5 1 1~25 4 1 1~26 3 1 1~27 2 1 1~28 1 1 1~29 Annex A /B/F/G (4-wires)

Strona 116

57 24 1 2,4,6 23 1 1,3,5,7 22 1 2,4,6,8 21 1 1,3,5,7,9 20 1 2,4,6,8,10 19 1 1,3,5,7,9,11 18 1 2,4,6,8,10,12 17 1 1,3,5,7,9,11,13 16 1 2,4,6,8,10,12,14

Strona 117 - 5.5 Reboot

58 Case 11 T1(framed)+ Serial interface Å---------Æ T1(framed) Case 12 T1(framed)+Ethernet interface Å---------ÆT1(framed)

Strona 118 - 5.6 View the system status

59 Table of T1+ Serial interface to T1 interface and T1+Ethernet interface to T1 interface mode on both sides Annex A /B/F/G (2-wires) E1 interface

Strona 119

4.4 SHDTU03B-31... 69

Strona 120

60 7 1 1,3,5,7,9,11,13,15,17 6 1 2,4,6,8,10,12,14,16,18 5 1 1,3,5,7,9,11,13,15,17,19 4 1 2,4,6,8,10,12,14,16,18,20 3 1 1,3,5,7,9,11,13,15,17,19,21 2 1

Strona 121

61 3.6 Sub-menu tree for REBOOT SYSTEM REBOOT SYSTEM -> * REBOOT * YES -> press ”ENTER” key Some settings request system reboot for the sett

Strona 122 - 5.6.3. View the Statistics

62 3.7 Sub-Menu tree for DIAGNOSTIC 3.7.1. Loopback function SYSTEM DIAGNOSTIC Î DIAG LOOPBACK Note : there is no SYSTEM DIAGNOSTIC menu on the

Strona 125

65 3.7.2. BER Test function SYSTEM DIAGNOSTIC Î DIAG BER TEST This is the internal Bit Error Rate Tester (BERT) for complete testing of local and

Strona 126

66 4. Parameters Table There are many parameters tables for end user easily to write down all setting of devices before installing those on sites.

Strona 127

67 4.2 SHDTU03b-Data 4.2.1. SHDTU03b-Data -- Serial interface mode NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A □B □F □G PSD

Strona 128

68 4.3 SHDTU03b-ET100 4.3.1. SHDTU03b-ET100 -- Ethernet interface mode NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A □B □F

Strona 129

69 4.4 SHDTU03b-31 4.4.1. SHDTU03b-31 -- E1 Interface mode Interface E1 □Serial □Ethernet □E1+Serial □E1+Ethernet NTU Type □STU-R □STU-

Strona 130

6. APPENDIX ...

Strona 131

70 4.4.2. SHDTU03b-31 -- Serial Interface mode Interface □E1 Serial □Ethernet □E1+Serial □E1+Ethernet NTU Type □STU-R □STU-C-INTCLK □

Strona 132

71 4.4.3. SHDTU03b-31 -- Ethernet Interface mode Interface □E1 □Serial Ethernet □E1+Serial □E1+Ethernet NTU Type □STU-R □STU-C-INTCLK

Strona 133

72 4.4.4. SHDTU03b-31 -- E1+Serial Interface mode Interface □E1 □Serial □Ethernet E1+Serial □E1+Ethernet NTU Type □STU-R □STU-C-INTCLK

Strona 134

73 4.4.5. SHDTU03b-31 -- E1+Ethernet Interface mode Interface □E1 □Serial □Ethernet □E1+Serial E1+Ethernet NTU Type □STU-R □STU-C-INTCLK

Strona 135 - 5.8 Upgrade

74 4.5 SHDTU03b-E1/T1 4.5.1. SHDTU03b-E1/T1 -- E1 Interface mode Interface E1 □T1 NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A

Strona 136

75 4.5.2. SHDTU03b-E1/T1 -- T1 Interface mode Interface □E1 T1 NTU Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK Annex □A □B □F □G PSD

Strona 137

76 4.6 SHDTU03b-31T 4.6.1. SHDTU03b-31T -- E1 Interface mode Interface E1 □Serial □Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+E

Strona 138

77 4.6.2. SHDTU03b-31T -- T1 Interface mode Interface □E1 □Serial □Ethernet □E1+Serial □E1+Ethernet T1 □T1+Serial □T1+Ethernet NTU Type □

Strona 139 - 5.9 Diagnostic

78 4.6.3. SHDTU03b-31T -- Serial Interface mode Interface □E1 Serial □Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+Ethernet NTU Ty

Strona 140

79 4.6.4. SHDTU03b-31T -- Ethernet Interface mode Interface □E1 □Serial Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+Ethernet NTU

Strona 142 - 5.10 Exit

80 4.6.5. SHDTU03b-31T -- E1+ Serial Interface mode Interface □E1 □Serial □Ethernet E1+Serial □E1+Ethernet □T1 □T1+Serial □T1+Ethernet NT

Strona 143

81 4.6.6. SHDTU03b-31T -- E1 + Ethernet Interface mode Interface □E1 □Serial □Ethernet □E1+Serial E1+Ethernet □T1 □T1+Serial □T1+Ethernet

Strona 144 - 6. Appendix

82 4.6.7. SHDTU03b-31T -- T1+ Serial Interface mode Interface □E1 □Serial □Ethernet □E1+Serial □E1+Ethernet □T1 T1+Serial □T1+Ethernet NT

Strona 145

83 4.6.8. SHDTU03b-31T -- T1 + Ethernet Interface mode Interface □E1 □Serial □Ethernet □E1+Serial □E1+Ethernet □T1 □T1+Serial T1+Ethernet

Strona 146

84 5. Configuration with Console Port This chapter will deal with the details of configuration and operation of this product via console port with

Strona 147

85 5.1 Login Procedure At the start up screen, you will see: Press the SPACE key until the login screen appears. When you see

Strona 148

86 5.2 Window structure After you type the password, it will display the main menu. Above captured screen shows the common struc

Strona 149

87 5.3 Main Menu Summary The main menu is prompted as following: Menu Title Function Setup Use this menu to setup SHDSL type, SHDSL paramet

Strona 150

88 5.4 Configuration This section provides information about the configuration of SHDSL .Bis NTU. Follow the procedures: In the main menu, select

Strona 151

89 5.4.1. Configure NTU Interface Setup Interface

Strona 152 - 6.5 Console Cable

9 1. Introduction The G.SHDSL.bis NTU offers four different interfaces (E1,T1, Serial and Ethernet) connecting customers to high-speed TDM servi

Strona 153 - 6.6 E1/T1 Balanced Cable

90 If the SHDSL.bis NTU is a multi-interface model, it will display more types of interfaces that can be selected. Use the [TAB] key to choose the dif

Strona 154 - 6.7 E1 Unbalanced Cable

91 5.4.2. Configure SHDSL parameters This section shows how to setup the SHDSL parameters: SHDSL Mode, Annex type, Psd Mask, SNR margin. Select Sh

Strona 155 - 6.8 Ethernet Cable

92 To set the SHDSL Annex type, move the cursor to Annex and press [ENTER]. Select the annex type by using [TAB] key. Set Up SHDSL parameter, Annex

Strona 156 - 6.9 DSL Cable

93 To set the SHDSL Margin, move the cursor to margin and press [ENTER]. Select the margin via [TAB] key and key in the Next margin. Setup SHDSL para

Strona 157 - 6.10 Power Cord

94 5.4.3. Configure E1 parameters When using E1 interface, select the E1 item and press [ENTER] or [RIGHT]. The E1 setting includ

Strona 158 - Å----ÆPIN5

95 Framing Framing is required to recover the channelized E1. In transparent operation, the framing is configured as Unframed. In this case the G.SH

Strona 159 - Å---ÆPIN20

96 FAS Data Data Data Data Data Data Data Data01234567831Time Slots64k 64k 64k 64k 64k 64k 64k 64k 64k 64k1408k9 ~ 30 ITU 991.2 (2004) (G.SHD

Strona 160

97 FAS01234 1631Time Slots64k 64k 64k 64k 64k 64k 64k896k17 ~ 30CAS5 ~ 15704kData Data Data Data Data Data Data Data Data Data Data01234567831Time Slo

Strona 161

98 Setup E1 Parameter, Pass Through When SHDSL.bis using 2-pairs(4-wires), the time slot number can only use even number When se

Strona 162

99 For example, when channel framing is PCM30 or PCM30C (with time slot number is 30 and first time slot is 1) refer to the following graphic. When P

Komentarze do niniejszej Instrukcji